Steam-brite.com


  Steambrite » Machine & Equipment » Parts & Accessories » Electrical Adapter Temporary Power Boxes » 20240537 My Account  |  Cart Contents  |  Checkout   
 
210-662-9000 LARGEST SELECTION AND LOWEST PRICES ON THE INTERNET: GUARANTEED!


Quick Find
 
Use keywords to find the product you are looking for.
Advanced Search
Steambrite
About Us
Privacy Notice
Conditions of Use
Contact Us
Sitemap
Shipping & Returns
What's New? Carpet Cleaning Equipment
AR Pump XWF10GE-G Pump/Gearbox 10G
AR Pump XWF10GE-G Pump/Gearbox 10G
$849.99

Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537]


Your Price:
Part Number: 20240537
Guaranteed: We will beat their price!
Quantity:
Estimated shipping cost: $ 18.00

Download information on the Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537]


Reviews




Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537]
Steambrite's Electrical Adapter Temporary Power Boxes - Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537].
If you can find a lower advertised price on the Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537] - 20240537, contact us at 210-662-9000,
and we will beat their price! Guaranteed!

host carpet cleaning machine air duct cleaning machine N/A window cleaning equipment closet dehumidifier wholesale carpet cleaning supply chemical cleaning etc pressure system wholportable carpet extractor dehumidifier rating N/A cleaning equipment used truck mount carpet cleaning equipment cleaning equipment pressure washercarpet cleaning equipment rental N/A rx20 hydramaster truckmount carpet clean equipment N/A carpet cleaning machine to buy cheap dehumidifiermold remediation aprilaire dehumidifier office cleaning equipment truck mount carpet cleaning equipment cleaning computer equipment windsor carpet extractor N/A bissell carpet cleaning machine N/A carpet steam cleaning equipment commercial floor cleaning equipment


Power Cord Adapter Inverter (Reverse Converter) Takes two 115 volt outlets and allows you to use 230 volt appliances that uses under 20 amp @ 230 volts (4600 watts) Single phase current to NEMA 10-20R receptacle.   Commonly used as an electric wall unit air conditioner.  Fast and easy 240 volts. This part number we use the outlet below!

make 220 volt from regular wall outlets to nema 10-20R
Bundle includes:




 
Square D HEPD80 Whole Home Electronics Protective Device, AC Surge Protection, Type 1 SPD, 120/240VAC, 1Phase 3Wire, 80kA Square D HEPD80 Whole Home Electronics Protective Device, AC Surge Protection, Type 1 SPD, 120/240VAC, 1Phase 3Wire, 80kA
F
actory Installed 600 Volt 80,000 Amp Surge Protection
HEPD devices protect and provide surge suppression for important items that are not compatible with plug strips such as electric cars, concrete grinders, concrete compression testing equipment, floor sanders, concrete dust and hepa vacuums, laser and light show equipment, washers, dryers, refrigerators, stoves, heating and air conditioning equipment, and lighting.
   




 
Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20 amp 115 Volt To allow 230 Volt 3 wire Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20 amp 115 Volt To allow 230 Volt 3 wire
   








Other 220 to 240 volt receptacles available including but not limited to: NEMA 6-30R, NEMA 6-50R, NEMA 10-30R, more
power converter systemNema 6-50R 240 volt
nema 3 wire configurations
nema 3 wire configurations

Works with Duosida and Jekayla, Level 2 Electric Vehicle Charger by ReadyCharge for faster charging speeds.  Compatible with Chevy Volt, Ford Energi, Toyota Prius, and Ford Evo.  Perfect for electric cars (BEV), pressure washers, welders, plasma cutters, vapor steam cleaners, wall air conditioners and other high powered equipment when 230 volt plugs are just not available. Tesla (BEV) car owners historically have purchased the 14-30R or 14-50R model wall AC units use the 6-20R

Not for use on GFCI or LDCI 115 volt Outlets or for use in the rain.

To use simply plug into different standard 120 volt wall outlets and push the momentary button to test voltage.  If the green light turns on, you are good to go.  Not all outlet combinations will produce the correct voltage so you have to test before each use or each time you take your box to a new location.  If you push the voltage test button and the green light does not turn on, simply re-located one of the power cords to a different location and retest.  Every job site location has the ability to provide 230 volts.  If you use 15 amp 115 v to 120 volt circuits then you will only be able to operate 15 amp 230 volt equipment.  If your pressure washer needs 23 amps @ 230 volts and you are plugged into 20 amp 115 volt outlets, you will need to turn the pressure down to lower the amp draw.  Just turn the pressure regulator / unloader knob counter clockwise.  The less pressure, the less horse power is needed to turn the electric motor and this will lower the amp draw.  
quick 220 reverse converter for joining ac plug

electrical power converter with heavy duty feet
tesla and electric car charger converter
 

Plastic Box is 6" X 6" X 4"
Dual 12-3 X 25 ft power cords with dual 20 amp push breakers.
Green Light Voltage Notification
Rubber feet on bottom of box or hang on the wall.
Until both 120 volt power cords are connected to a 120 volt electrical source, it is electrically isolated from the electrical circuit of the exposed male plug on the 2nd power cord.  This protects the user from accidental shock through the exposed male plug contact.
You must test both wall outlets with a receptacle polarity tester before use!
20100823   Electrical Outlet Receptacle Tester 3 wire 120 volt   Electrical Outlet Receptacle Tester 3 wire 120 volt 
Note: User assumes all responsibility on use.  It is the users responsibility to check the inbound voltage,electrical joiner box outbound voltage, and total amp draw to verify these are not going to be overloaded.  The user agrees to test the amp draw of any appliance or machine that they plug into these converters to ensure they are not being overloaded. Meters are cheap and mistakes are expensive.  You can purchase a meter at https://www.steam-brite.com/voltage-meter-mulitester-p-6259.html 
User agrees to hold Steam Brite, its employees, and agents harmless in the event of any use of said use of converter.  The user agrees to not hold SteamBrite and all employee against any problems that arise out of the use of said converters/ inverters.  Remember, just because it plugs in does not mean it is OK to use!

Please remember the 80/20 electrical rule.  If you are going to plug into a 15 amp outlet and draw long term the device needs to be under 80% of 15 amps = 12 amps max.
If I plug into dual 20 amp breakers long term then the 80/20 rules math is 20 amps X 80% = 16 amps max.

Manufacture 1 Yr warranty.  Add optional 2 or 4 more years for a little more.
Owners Manual
       


Tips:  One customer wrote, "I plugged into different walls, not the same outlet, and it did not work."

Answer:  This is incorrect step / understanding. understanding left phase vs right phase in a breaker panel

In order to have the power supply box work, it must be plugged into different phases.

There are two phases of power in every home.

Half of all the outlets are on left phase, and the other half is on right phase.

You must land on one of each phase in order for the power supply to work.

This means if I just randomly select two outlets in a home, I could be plugged into:  two left side phases, 2 right side phases, or 1 of left + 1 right (correct use of power supply, depress phase locator button on the power supply box and will illuminate bright green on the phase locator light if you plugged in correctly.)

If you look at the breaker panel (photo to the right) and notice the column of breakers on the left side and then a column on the ride side.

The way a breaker box is wired is the top left breaker is left phase, the 2nd from the top left strait down the left column is right phase, 3rd down is left column is left phase, 4th down is right phase.  These breakers alternate phase location all the way down each column.

The top right column of breakers works exactly the same way.  You have to land on one left phase and and one right phase to make this item work.  It is OK to have landed on a pair of outlets that is left and right side and each is positioned anywhere in the breaker panel.

Since this power supply box will not work with GFCI or LCI outlets you can also replace a GFCI outlet with a standard wall receptacle.  

Optionally, if the two breakers you want to use are on the same phase, simply change the location of one of the two breakers to be in a different position in the column.   This is very easy to do and only takes a screw driver (see video link below.)  Go outside and turn off the breaker and turn off the breaker that is labeled as ‘main.’  Go back to the garage and take off the garage panel cover.  Grab the breaker you want to relocate and simply switch positions with another breaker either one up or one down in the column.   You can change the location of the breaker or change the location of the wire in the breaker (your choice.)  This will put the breaker on a different phase.  Again, see video below on how to do this.

https://youtu.be/BG9I-PokSdI?si=m06267ZWR54Tiknu

and
https://youtu.be/IzTV9t7bnH8?si=p1lgRxxO5gsEvmub

Once you are on different phases, and press the momentary phase location button on your power supply box, the green light will be bright green telling you, you selected one left and one right phase and you are good to use this power supply box below the required amp draw of the wall outlets you plugged into.

 


Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537]
Steambrite's Electrical Adapter Temporary Power Boxes - Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537] is .
If you can find a lower advertised price on the Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537] - 20240537,contact us at 210-662-9000,
and we will beat their price! Guaranteed!

air cleaning discount duct houston tx house dehumidifier N/A carpet cleaning equipment manufacturer industrial vacuum cleaner air cleaning duct equipment used dry cleaning equipment for sale carpet cleaning equipment hornet truckmount N/A cleaning equipment best carpet cleaning machine hornet truckmount carpet cleaning floor home machine N/A industrial vacuum cleaner bionaire dehumidifier N/A castex carpet extractor carpet cleaning equipment mold remediation hampton bay dehumidifier used carpet extractor carpet cleaning product frigidaire dehumidifier marine dehumidifier N/A mold remediation N/A crawl space dehumidifier carpet cleaning equipment professional

Product Options
This product was added to our store on Tuesday 04 June, 2024.
Reviews Add to Cart
Steambrite Carpet Cleaning Equipment Truckmount Truck Mount Truckmounted Extractor

Steambrite will ship the Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537 [20240537] by either Fedex or Freight Quote, and are normally shipped within 1-10 working days. Please remember it takes 6-8 working days for you to receive your order after shipment, and ground shipping times are not guaranteed. Next day and two day service are available. Click here for our full shipping policy. Specifications subject to change without notice.
Shopping Cart Carpet Cleaning Equipment
Click here to review
Manufacturer Info
Other products
Notifications Carpet Cleaning Equipment
Notify me of updates to Clean Storm Reverse10-20R Power Joiner Step Up Inverter Electric AC Converts Dual 20A 120V To 230V 3Wire 80Ka Surge 20240537
Specials Carpet Cleaning Equipment
Husqvarna 967977406 HTC T5 PG540 Duratiq 5 Concrete Grinder Vacuum A2000 HEPA 12947485 805544251907
Husqvarna 967977406 HTC T5 PG540 Duratiq 5 Concrete Grinder Vacuum A2000 HEPA 12947485 805544251907
$20,056.64
$17,056.64
What's New? Carpet Cleaning Equipment
Clean Storm 20241132 Air Duct Cleaning Reverse Blast Assembly with Male Air Chuck Plug QD Installed
Clean Storm 20241132 Air Duct Cleaning Reverse Blast Assembly with Male Air Chuck Plug QD Installed
$31.69
Reviews Carpet Cleaning Equipment
Write a review on this product!
Videos
portable carpet extractor

Accepted Credit Cards & Paypal
1982 - 2018 Steambrite Supply
Carpet Cleaning Machines||Truck Mount Machines